Latest News Archive

Please select Category, Year, and then Month to display items
Previous Archive
24 July 2023 | Story André Damons | Photo Supplied
Tyla Baker
Tyla Baker, a postgraduate student in the Department of Microbiology and Biochemistry at the University of the Free State (UFS).

Yeast and other filamentous fungi, which pose a great risk to the health of immune-compromised or suppressed individuals, can be found in various drinking water sources such as ground, spring, surface, and tap water. These opportunistic pathogens may cause severe to fatal infections and can range from superficial to bloodstream or systemic infections.

This is according to Tyla Baker, a postgraduate student in the Department of Microbiology and Biochemistry at the University of the Free State (UFS). She is studying for her MSc degree in Microbiology under the supervision Prof Carlien Pohl-Albertyn, National Research Forum (NRF) SARChI Research Chair in Pathogenic Yeasts. Prof Jacobus Albertyn and Dr Jolly Musoke are her co-supervisors.

Baker says the fungi in the water highlights that current water treatment processes are not efficient in their removal from water destined for household use. “These infections may not be harmful to people with healthy immune systems, but do pose a great risk to the health of immune-compromised or suppressed individuals. 

Definite possibility to contract fungal infections from polluted water 

“As the number of people with immune systems that are less functional (e.g. premature babies, elderly persons, people with cancer, diabetes or other serious diseases, HIV+ persons, transplant patients) increases, the number of people at risk of fungal infection also increases,” says Baker.

According to Baker, a previous study done in Brazil has identified yeast in bottled mineral water as well as municipally supplied tap water. The potential risk to contract fungal infections from polluted water sources is a definite possibility but more research is required to fully understand and determine the level of risk and the extent of its effects, she says. In the context of Mangaung, it is a concern that untreated water from sewage works as well as other sewage often leaks into the environment (as evidenced by numerous recent articles in local newspapers). These waters are potential carriers of large numbers of pathogens (including pathogenic yeasts/fungi) that may increase the risk to people coming into contact with it.

Baker says there is a good chance people are consuming these kinds of micro-organisms daily, considering that yeast and other filamentous fungi can also form biofilms inside pipes and spread as the impact of water flow dislodges these cells. “People will not even be aware that they are consuming these micro-organisms, some fungi are considered nuisance microbes and may cause a change in the smell and taste of water which may act as an indicator that the water is contaminated, but tests would be needed to confirm this,” she says.

The effects of consuming these fungi are still a grey area of research since the full extent of the consumption of yeast is still unknown, but there are studies being conducted to elucidate the full impact of this occurrence, says Baker. The risk depends on the immune status of the person, the specific species of yeast/fungus ingested, and the number of cells/spores ingested.

Culture-dependent and independent methods

 “It is important to know that many pathogenic yeasts and other fungi are opportunistic pathogens, meaning they infect individuals whose immune systems are compromised due to various reasons such as illness (HIV/AIDS, cancer, TB etc.), undergoing organ transplants or even something as simple as using antimicrobial agents such as antibiotics. 

“Taking this into account, along with the HIV/AIDS statistics in South Africa, which has a prevalence rate of 13,7% with approximately 8,2 million people in 2021 living with HIV, these individuals are more susceptible to infection by these opportunistic pathogens. Some of these pathogenic yeasts are also multidrug resistant or show resistance to readily available antifungals, such as fluconazole, which hinders the ability of healthcare professionals to efficiently treat infections to avoid fatal/severe outcomes,” explains Baker.  

For her studies, she will be testing for fungi in water by using a combination of culture-dependent and independent methods to try and identify yeast present in wastewater. Baker says culture-dependent techniques will include culturing (growing) yeast on an appropriate medium while culture-independent techniques will include more intricate molecular work in the form of a multiplex PCR (polymerase chain reaction) which will enable her to identify an array of pathogenic yeasts present in samples.

According to Baker, people can stay safe by boiling water before drinking it, although temperatures above 100°C are required to kill most harmful microbes. Regular cleaning of shower heads and faucets help to prevent build-up which may act as a surface to which fungi will attach to and grow. Another way to stay safe is to maintain and regularly inspect water filters for damage and avoid contact with untreated sewage.

News Archive

UFS implements access control measures on our Bloemfontein Campus
2014-11-21



Photo: Hannes Pieterse

Online Application form: non personnel

Map with access gates on the Bloemfontein Campus


Accessing the Bloemfontein Campus from 3 November 2014

Access control during major events on the Bloemfontein Campus

Q&A




The University of the Free State (UFS) has been tightening security measures on its Bloemfontein Campus for quite some time now. Purposefully, we have consolidated several safety measures to keep our students, staff and visitors – the heartbeat of our university – protected.

Our most significant step in this endeavour is now in the process of implementation. All five entrance gates to the campus are being equipped with strict access control.

The first phase of the process was implemented beginning of August 2014. Gates 2 (Badenhorst Street) and 4 (Furstenburg Street) were equipped with card readers. Only persons with valid access cards can enter and leave through these gates. Existing staff and student cards are equipped to be read by the short-distance card readers at the gates in order to activate the booms.

At this stage, staff and students are swiping their cards against the card readers at Gates 2 and 4 or holding it not further than 20 mm from the reader for the boom to open. Card holders now physically stop in front of the boom in order to get access to the campus.  

The duel-frequency card:

The dual-frequency cards available at the Card Division on the Thakaneng Bridge are currently out of stock. New cards will be delivered on Friday 14 November 2014.

The special offer of R30 per access card has been extended to the end of November 2014. To qualify for this offer, staff and students may pay the R30 for a dual-frequency card at the bank or cashiers on the Thakaneng Bridge no later than 28 November.  The cost of dual-frequency cards will increase to R60 per card from 1 December 2014.

Please note that only people with vehicles need to apply for dual-frequency cards.

Students and staff will, however, still be able to gain access to the Bloemfontein Campus with their current cards (in the case of staff and students who haven’t purchased dual-frequency cards yet). As is currently the practice at the gates in Furstenburg and Badenhorst Streets, you will have to stop when you reach the boom, swipe your card past the card reader, the boom will open and you will be able to drive through.

Staff and students using their dual-frequency cards should:

-       Reduce speed
-       Hold the card in a vertical position at the driver’s side window, in the direction of the long-distance reader (see photo)

It is therefore not necessary to stop in front of the boom. On holding your card upright, in line with the card reader, the gate will open automatically and you will be able to drive through (keep your card outside your window; the card reader cannot operate through tinted windows).

Please note that this arrangement only applies to incoming lanes. On leaving the campus, the card has to be swiped. This is due to the number-plate recognition technology installed at exits for additional security.

If the long-distance reader does not work, the dual-frequency card can still be used at a tag reader. 

Applying for your new card:

Electronic fund transfers: Absa Bank: 1 570 8500 71, Ref: 1 413 07670 0198, OR pay the R30 at the UFS Cashiers, Thakaneng Bridge. Please note that the price of the cards will increase to R60 from 1 November 2014.

Take your existing personnel or student card, together with proof of payment, to the UFS Card Division, Bloemfontein Campus, Thakaneng Bridge, to have your photo taken and your new dual-frequency card issued.

Permission to access specific UFS buildings or facilities linked to your existing card, will be automatically linked to the new card.

The new card is marked ‘dual’ on the back in the right, bottom corner.

The UFS Cashiers will provide assistance between 09:00 and 14:30, and the UFS Card Division between 09:00 and 15:00.

Implementation of full access control


Full access control will be implemented on the UFS’s Bloemfontein Campus from 3 November 2014. This means that access control will be implemented at all gates on the Bloemfontein Campus.

Who is using which gate? See Q&A for more information.


Gate 3 (Wynand Mouton Drive) is earmarked for use by official card holders. These include students, staff and persons doing business on campus. Parents dropping and fetching their children for sports, as well as service providers of the UFS, such as architects, may apply for valid cards. These persons will have to provide proof that they have business on campus (complete online application form and sign declaration).

All visitors to the campus will be referred to the Visitor’s Centre at Gate 5 (DF Malherbe Drive). This include, among others, parents, family and friends of students, as well as conference delegates. It is estimated that the Visitor’s Centre will be completed at the end of November (note that the gate at DF Malherbe Drive will be operational by 3 November 2014). Visitors will sign in at the Visitor’s Centre and, depending on the business they have on campus, they will only be allowed on campus for a certain period of time.

•    Lane 1 at Gate 5 will be used by visitors and service providers to enter the campus. Only card holders will be able to use lane 2.
•    Buses and trucks can also enter the campus through Gate 5.

The construction at the Main Gate at Nelson Mandela Drive is to build one extra lane for incoming traffic. The project is estimated to be completed at the end of October 2014.

•    For outgoing traffic, lane 1 (furthest from the guardhouse) and lane 2 will only be used by card holders and lane 3 (closest to the booth) will be used by service providers.
•    For incoming traffic, lanes 2 and 3 were set aside for use by only service providers. Lanes 1 and 4 will be used by only card holders.

Pedestrians

All gates for motorists will also be equipped with a pedestrian thoroughfare on completion of the project. Persons using these pedestrian gates also need to use their cards to get access to the campus.

Pedestrians who are visitors, but aren’t in possession of a valid access card, should please go to the Visitor’s Centre at the gate in DF Malherbe Drive where they will be helped.

More information

For more information on access control at the UFS, please watch our videos and read the Q&A or e-mail your enquiries to accesscontrol@ufs.ac.za.  


Issued by:    Lacea Loader (Director: Communication and Brand Management)
Tel: +27(0)51 401 2584 | +27(0)83 645 2454
E-mail: news@ufs.ac.za


We use cookies to make interactions with our websites and services easy and meaningful. To better understand how they are used, read more about the UFS cookie policy. By continuing to use this site you are giving us your consent to do this.

Accept