23 November 2021 | Story Leonie Bolleurs | Photo Tania Allen
Dr Jana Vermaas and Ketshepileone Matlhoko are working on research that leaves your washing clean and fresh without the use of any detergents, which is also beneficial to the environment.

Cold water or hot water? Omo or Skip? Laundry blues is a reality in most households and when you add stains to the equation, then what was supposed to be part of your weekly household routine, becomes frustrating and time consuming. 

Researchers at the University of the Free State (UFS) are conducting research that is putting a whole new environmentally friendly spin on laundry day.

Sustainability and environmental conservation

Dr Jana Vermaas, Lecturer in the Department of Sustainable Food Systems and Development at the UFS, is passionate about textiles and sustainability – almost a decade ago, she conducted a study on the efficacy of anolyte as a disinfectant for textiles.

She describes the process: “During electrochemical activation, a dilute solution of natrium chloride/salt passes through a cylindrical electrolytic cell where the anodic and cathodic chambers are separated. Two separate streams of electrochemically activated water are produced. Anolyte as water was produced at the positive electrode and has a low pH, high oxidation-reduction potential and contains dissolved chloride, oxygen, and hydroxyl radical. It also has an antimicrobial effect.”

The benefits of this process are in line with her enthusiasm for environmental conservation. 

According to Dr Vermaas, the amount of water and chemicals used to clean textile articles is massive. “Chemicals used to disinfect, for example, hospital laundry, are hazardous. Not all laundries in the industry have a closed loop system or try to remove the chemicals before the wastewater is discarded.”

“Different amounts of detergents have various effects on our fauna and flora. Due to their low biodegradability, toxicity, and high absorbance of particles, detergents can reduce the natural water quality, cause pH changes in soil and water, lead to eutrophication (too many nutrients), reduce light transmission, and increase salinity in water sources.”

“But with the catholyte and anolyte process, water returns to its original status, which means that the water solution becomes inactive again after production where it existed in a metastable state while containing many free radicals and a variety of molecules for 48 hours. Thus, no chemicals are left in the wastewater. The water can therefore be recycled, not as potable water but, for example, to flush toilets or to water plants.

“We should do what we can to save water,” she says. 

Should you, like Dr Vermaas, also feel strongly about protecting the environment and want to obtain one of these machines that leaves your washing clean and fresh without the use of any detergents, you will be able to find such an appliance in South Arica. However, it does not come cheap. “It is a bit costly for residential use, but might be more accessible in the future,” states Dr Vermaas, who is of the opinion that it is a more sustainable option for commercial laundries.

Detergency properties and colourfastness 

Recently, more research has been conducted on this topic, but with a focus on the detergency properties of the catholyte to clean different textile fibres (natural and synthetic). Catholyte, she explains, is water produced at the negative electrode with a high pH, low oxidation-reduction potential, containing alkaline minerals. It also has surface active agents that increase the wetting properties, and it is an antioxidant. 

“A master’s student in the department, Ketshepileone Matlhoko, will be submitting her dissertation at the end of November on the possibility of using the catholyte as a scouring agent to clean raw wool,” says Dr Vermaas. 

The department is also conducting studies to investigate the influence of both catholyte and anolyte on colourfastness.

*Graphic: Production of electrolysed water (Nakae and Indaba, 2000). Diagram: Supplied



News Archive

UFS responds to revocation of the accreditation of the SA Doping Control Laboratory by WADA
2017-07-01

The World Anti-Doping Agency (WADA) yesterday informed the South African Doping Control Laboratory (SADoCoL) at the University of the Free State (UFS) that the WADA accreditation status of the laboratory has been revoked.

This revocation does, however, not include the analysis of blood samples for the Athlete Biological Passport for which SADoCoL has been re-accredited in August 2016 and which the laboratory will continue to perform. It also does not impact at all on the testing of urine sport samples by the South African Institute of Drug-free Sport (SAIDS), who will continue to send such samples for testing to other WADA accredited laboratories, while blood samples will be tested at SADoCoL as before.

The revocation follows a year long period of suspension in which the laboratory had to develop its analytical capabilities and instate new systems and methodologies.  “In this period the laboratory worked diligently to realize all of these requirements and according to an inspection team from the WADA Laboratory Expert Group who visited the laboratory in February 2017, much has been done and the Laboratory is in a much better state than it was before the suspension in May 2016,” says prof Marthinus van der Merwe, Director of SADoCoL.

“However, there were certain aspects of these requirements that the laboratory could not achieve within the time-frame stipulated by WADA and therefore the organisation is bound by its rules and regulations to now revoke the accreditation status of the laboratory. Since much effort and resources have been invested in the laboratory in the last two years, the management of SADoCoL together with senior leadership of the UFS decided to go ahead and finalise all development in order to re-apply for WADA accreditation,” says prof van der Merwe. 

“The UFS fully acknowledges the hard work of SADoCoL during the period of development and is committed to support the laboratory in its endeavors to re-attain its status within the very specialised and highly regulated community of world-wide doping control laboratories.  The premium goal of the laboratory is still to fully serve the sporting community of South Africa and Africa according to the WADA guidelines for anti-doping control in Sport and it is confident to attain that with the support of all role players in this field,” says Prof Witthuhn, Vice-Rector: Research at the UFS.

Released by:
Lacea Loader (Director: Communication and Brand Management)
Telephone: +27 51 401 2584 | +27 83 645 2454
Email: news@ufs.ac.za | loaderl@ufs.ac.za
Fax: +27 51 444 6393

We use cookies to make interactions with our websites and services easy and meaningful. To better understand how they are used, read more about the UFS cookie policy. By continuing to use this site you are giving us your consent to do this.

Accept