Latest News Archive

Please select Category, Year, and then Month to display items
Previous Archive
23 November 2021 | Story Leonie Bolleurs | Photo Tania Allen
Dr Jana Vermaas and Ketshepileone Matlhoko are working on research that leaves your washing clean and fresh without the use of any detergents, which is also beneficial to the environment.

Cold water or hot water? Omo or Skip? Laundry blues is a reality in most households and when you add stains to the equation, then what was supposed to be part of your weekly household routine, becomes frustrating and time consuming. 

Researchers at the University of the Free State (UFS) are conducting research that is putting a whole new environmentally friendly spin on laundry day.

Sustainability and environmental conservation

Dr Jana Vermaas, Lecturer in the Department of Sustainable Food Systems and Development at the UFS, is passionate about textiles and sustainability – almost a decade ago, she conducted a study on the efficacy of anolyte as a disinfectant for textiles.

She describes the process: “During electrochemical activation, a dilute solution of natrium chloride/salt passes through a cylindrical electrolytic cell where the anodic and cathodic chambers are separated. Two separate streams of electrochemically activated water are produced. Anolyte as water was produced at the positive electrode and has a low pH, high oxidation-reduction potential and contains dissolved chloride, oxygen, and hydroxyl radical. It also has an antimicrobial effect.”

The benefits of this process are in line with her enthusiasm for environmental conservation. 

According to Dr Vermaas, the amount of water and chemicals used to clean textile articles is massive. “Chemicals used to disinfect, for example, hospital laundry, are hazardous. Not all laundries in the industry have a closed loop system or try to remove the chemicals before the wastewater is discarded.”

“Different amounts of detergents have various effects on our fauna and flora. Due to their low biodegradability, toxicity, and high absorbance of particles, detergents can reduce the natural water quality, cause pH changes in soil and water, lead to eutrophication (too many nutrients), reduce light transmission, and increase salinity in water sources.”

“But with the catholyte and anolyte process, water returns to its original status, which means that the water solution becomes inactive again after production where it existed in a metastable state while containing many free radicals and a variety of molecules for 48 hours. Thus, no chemicals are left in the wastewater. The water can therefore be recycled, not as potable water but, for example, to flush toilets or to water plants.

“We should do what we can to save water,” she says. 

Should you, like Dr Vermaas, also feel strongly about protecting the environment and want to obtain one of these machines that leaves your washing clean and fresh without the use of any detergents, you will be able to find such an appliance in South Arica. However, it does not come cheap. “It is a bit costly for residential use, but might be more accessible in the future,” states Dr Vermaas, who is of the opinion that it is a more sustainable option for commercial laundries.

Detergency properties and colourfastness 

Recently, more research has been conducted on this topic, but with a focus on the detergency properties of the catholyte to clean different textile fibres (natural and synthetic). Catholyte, she explains, is water produced at the negative electrode with a high pH, low oxidation-reduction potential, containing alkaline minerals. It also has surface active agents that increase the wetting properties, and it is an antioxidant. 

“A master’s student in the department, Ketshepileone Matlhoko, will be submitting her dissertation at the end of November on the possibility of using the catholyte as a scouring agent to clean raw wool,” says Dr Vermaas. 

The department is also conducting studies to investigate the influence of both catholyte and anolyte on colourfastness.

*Graphic: Production of electrolysed water (Nakae and Indaba, 2000). Diagram: Supplied



News Archive

An incident-free recess for the UFS
2010-07-19

The improved security measures at the University of the Free State (UFS) have resulted in an incident-free recess on the Main Campus in Bloemfontein during the 2010 FIFA World Cup and the annual Volksblad Arts Festival.

The UFS provided accommodation for international spectators visiting the country for the World Cup and recently also hosted the hugely popular Volksblad Arts Festival without any security glitches.

These successes could be attributed to the hard work of staff members from various divisions at the UFS to ensure that the security was improved.

“The main question we had to deal with was: should our Main Campus be fenced off? This matter had been under discussion for quite some time. In order to ensure the feasibility thereof, a second impact study was done by a consulting engineer,” said Prof. Niel Viljoen, Vice-Rector: Operations at the UFS.

“This study has shown that, given the nature of activities on the campus and the access configuration, it would be difficult, if not impossible, to effectively control access to the campus, especially as far as visitors were concerned. Any type of access control measure would result in delays at the gates, which could have a major impact on the traffic flow, delays, costs and emissions.”

“It is important that our staff and students feel safe on the Main Campus, whether they are walking on campus or working in their offices. In that way we can ensure an environment that is conducive to staff and students to work and study,” he said.

Various measures are being implemented to make the campuses safer. These include, among others:

  • The installation of alarms in buildings on the Main Campus. The project for the South Campus has been completed and the installation of a new alarm system on the Qwaqwa Campus will start soon.

     
  • Staff and students will be required to wear identification cards once the new identification system has been put in place. These cards will allow access to all buildings.

     
  • Fences around the Main Campus are being repaired and the areas around these fences are being cleaned. This project should be completed by August 2010.

     
  • Lights will be installed in badly lit areas on the Main Campus. The first phase of this project includes the area between the Mooimeisiesfontein, Welwitschia and Vergeet-my-nie residences. This project will also be completed by August 2010.

     
  • The walkways on the Main Campus will be patrolled more frequently and effectively.

     
  • Contracted security workers will be utilised more effectively.

     
  • The monitoring of security cameras on the Main Campus on a 24/7 basis. “For this purpose the security room of our Protection Services is in the process of being upgraded,” said Prof. Viljoen.

The possibility of placing security cameras and panic buttons in parking areas and walkways is investigated.

Media Release
Issued by: Mangaliso Radebe
Assistant Director: Media Liaison
Tel: 051 401 2828
Cell: 078 460 3320
E-mail: radebemt@ufs.ac.za  
16 July 2010

 

We use cookies to make interactions with our websites and services easy and meaningful. To better understand how they are used, read more about the UFS cookie policy. By continuing to use this site you are giving us your consent to do this.

Accept