Latest News Archive

Please select Category, Year, and then Month to display items
Previous Archive
23 November 2021 | Story Leonie Bolleurs | Photo Tania Allen
Dr Jana Vermaas and Ketshepileone Matlhoko are working on research that leaves your washing clean and fresh without the use of any detergents, which is also beneficial to the environment.

Cold water or hot water? Omo or Skip? Laundry blues is a reality in most households and when you add stains to the equation, then what was supposed to be part of your weekly household routine, becomes frustrating and time consuming. 

Researchers at the University of the Free State (UFS) are conducting research that is putting a whole new environmentally friendly spin on laundry day.

Sustainability and environmental conservation

Dr Jana Vermaas, Lecturer in the Department of Sustainable Food Systems and Development at the UFS, is passionate about textiles and sustainability – almost a decade ago, she conducted a study on the efficacy of anolyte as a disinfectant for textiles.

She describes the process: “During electrochemical activation, a dilute solution of natrium chloride/salt passes through a cylindrical electrolytic cell where the anodic and cathodic chambers are separated. Two separate streams of electrochemically activated water are produced. Anolyte as water was produced at the positive electrode and has a low pH, high oxidation-reduction potential and contains dissolved chloride, oxygen, and hydroxyl radical. It also has an antimicrobial effect.”

The benefits of this process are in line with her enthusiasm for environmental conservation. 

According to Dr Vermaas, the amount of water and chemicals used to clean textile articles is massive. “Chemicals used to disinfect, for example, hospital laundry, are hazardous. Not all laundries in the industry have a closed loop system or try to remove the chemicals before the wastewater is discarded.”

“Different amounts of detergents have various effects on our fauna and flora. Due to their low biodegradability, toxicity, and high absorbance of particles, detergents can reduce the natural water quality, cause pH changes in soil and water, lead to eutrophication (too many nutrients), reduce light transmission, and increase salinity in water sources.”

“But with the catholyte and anolyte process, water returns to its original status, which means that the water solution becomes inactive again after production where it existed in a metastable state while containing many free radicals and a variety of molecules for 48 hours. Thus, no chemicals are left in the wastewater. The water can therefore be recycled, not as potable water but, for example, to flush toilets or to water plants.

“We should do what we can to save water,” she says. 

Should you, like Dr Vermaas, also feel strongly about protecting the environment and want to obtain one of these machines that leaves your washing clean and fresh without the use of any detergents, you will be able to find such an appliance in South Arica. However, it does not come cheap. “It is a bit costly for residential use, but might be more accessible in the future,” states Dr Vermaas, who is of the opinion that it is a more sustainable option for commercial laundries.

Detergency properties and colourfastness 

Recently, more research has been conducted on this topic, but with a focus on the detergency properties of the catholyte to clean different textile fibres (natural and synthetic). Catholyte, she explains, is water produced at the negative electrode with a high pH, low oxidation-reduction potential, containing alkaline minerals. It also has surface active agents that increase the wetting properties, and it is an antioxidant. 

“A master’s student in the department, Ketshepileone Matlhoko, will be submitting her dissertation at the end of November on the possibility of using the catholyte as a scouring agent to clean raw wool,” says Dr Vermaas. 

The department is also conducting studies to investigate the influence of both catholyte and anolyte on colourfastness.

*Graphic: Production of electrolysed water (Nakae and Indaba, 2000). Diagram: Supplied



News Archive

Getting out of the dark
2015-04-28

Photo: Leonie Bolleurs

Since 2008, the University of the Free State has been busy with the planning and implementation of projects to reduce the impact of load shedding. To date,  the cost of these projects has run to R6 million. They have been done primarily to ensure that the academic programme does not suffer damage as a result of the increasing interruptions in the power supply that are continuing this year.

The university’s greatest concern has been the provision of emergency power to the lecture halls and laboratories.

Thus far, 35 generators are servicing 55 buildings on the three campuses of the UFS. This includes 26 generators on the Bloemfontein Campus, eight on the Qwaqwa Campus in the Eastern Free State, and one generator on the South Campus in Bloemfontein. The generators are already in service, and are maintained in working order.

Since 2010, the university has also ensured that all newly-built academic buildings are equipped with emergency power supplies.

On the South Campus in Bloemfontein, the new lecture-hall building and the computer laboratory are equipped with emergency power, while the installation of emergency generators in other buildings is under way. The majority of the buildings on the Qwaqwa Campus in the Eastern Free State are equipped with emergency power supplies.

In the meantime, the UFS management has approved a further R11 million for the installation of additional generators on the three campuses. A further R1.5 million has also been approved for the purchase of two mobile generators.

To extend the work already done, the main task will be the installation of more generators on the Bloemfontein Campus to ensure that lecture halls with emergency power will be available for the centrally-arranged timetables, and to ensure that more of the critical laboratories will be provided with emergency power.

There are still  some important buildings and halls on the Bloemfontein Campus that must be supplied with emergency power. However, it is a costly process and must be brought into operation gradually. The further implementation of emergency power depends on the delivery of equipment. The university is also investigating alternative solutions for power provisioning, including solar power.

Generators with spare capacity are optimally deployed to satisfy the lower needs of the campus, including the Odeion, the ANNEX at Microbiology, the Stabilis ANNEX, the Agriculture Building, the UV-Sasol library, and the Francois Retief Building.

In addition, the UFS  is busy on all campuses, coupling area lighting, including

street lights and pedestrian walkways, to existing generators. Procedures for the operation of mechanical equipment, such as entrance gates, lifts, and so on, are currently being dealt with on all campuses. Continuous power sources for certain ICT equipment will be installed on all campuses to protect it against power surges.

Staff and students can also equip themselves with the necessary knowledge to manage load shedding in their specific areas of work and study. It is always helpful to know who to contact. The following list with guidelines and contact numbers has been compiled to assist you:

1. In an emergency, call Protection Services. This line will continue to operate, regardless of whether the power is on or off.
2. Avoid using lifts just before planned load shedding. Some lifts have emergency power packs which will bring the lift to the nearest floor and open the doors. If you still get stuck in a lift during a power outage, use your cellphone to call Protection Services. While you're waiting, stay calm and be patient.
3. If the access control systems in your building stop working after load shedding, contact Protection Services.
4. The students and staff members who are most at risk during load shedding are those in wheelchairs or with other mobility limitations. As far as possible, plan ahead to avoid being stuck on a floor or in a room that is difficult to access when load shedding is imminent. Please contact Protection Services if you need assistance.
5. During a fire, alarms WILL go off. Alarms are not power driven, but battery driven. For assistance, contact Protection Services.
6. The main UFS Switchboard (Bloemfontein Campus +27(0)51 401 9111 and Qwaqwa Campus +27(0)58 718 5000) will continue to operate during load shedding.

Contact details of Protection Services:

  • Bloemfontein Campus: +27(0)51 401 2634/2911
  • Qwaqwa Campus: +27(0)58 508 5460/5175
  • South Campus: +27(0)51 5051217

Communication and Brand Management will make information available on the UFS web, Facebook page, Twitter, Blackboard and the intranet. Get the load shedding schedule from Eskom’s webpage (http://loadshedding.eskom.co.za/). The Bloemfontein Campus falls in group 4 and the South Campus falls in group 2 in Centlec’s load shedding schedule.

We use cookies to make interactions with our websites and services easy and meaningful. To better understand how they are used, read more about the UFS cookie policy. By continuing to use this site you are giving us your consent to do this.

Accept