23 November 2021 | Story Leonie Bolleurs | Photo Tania Allen
Dr Jana Vermaas and Ketshepileone Matlhoko are working on research that leaves your washing clean and fresh without the use of any detergents, which is also beneficial to the environment.

Cold water or hot water? Omo or Skip? Laundry blues is a reality in most households and when you add stains to the equation, then what was supposed to be part of your weekly household routine, becomes frustrating and time consuming. 

Researchers at the University of the Free State (UFS) are conducting research that is putting a whole new environmentally friendly spin on laundry day.

Sustainability and environmental conservation

Dr Jana Vermaas, Lecturer in the Department of Sustainable Food Systems and Development at the UFS, is passionate about textiles and sustainability – almost a decade ago, she conducted a study on the efficacy of anolyte as a disinfectant for textiles.

She describes the process: “During electrochemical activation, a dilute solution of natrium chloride/salt passes through a cylindrical electrolytic cell where the anodic and cathodic chambers are separated. Two separate streams of electrochemically activated water are produced. Anolyte as water was produced at the positive electrode and has a low pH, high oxidation-reduction potential and contains dissolved chloride, oxygen, and hydroxyl radical. It also has an antimicrobial effect.”

The benefits of this process are in line with her enthusiasm for environmental conservation. 

According to Dr Vermaas, the amount of water and chemicals used to clean textile articles is massive. “Chemicals used to disinfect, for example, hospital laundry, are hazardous. Not all laundries in the industry have a closed loop system or try to remove the chemicals before the wastewater is discarded.”

“Different amounts of detergents have various effects on our fauna and flora. Due to their low biodegradability, toxicity, and high absorbance of particles, detergents can reduce the natural water quality, cause pH changes in soil and water, lead to eutrophication (too many nutrients), reduce light transmission, and increase salinity in water sources.”

“But with the catholyte and anolyte process, water returns to its original status, which means that the water solution becomes inactive again after production where it existed in a metastable state while containing many free radicals and a variety of molecules for 48 hours. Thus, no chemicals are left in the wastewater. The water can therefore be recycled, not as potable water but, for example, to flush toilets or to water plants.

“We should do what we can to save water,” she says. 

Should you, like Dr Vermaas, also feel strongly about protecting the environment and want to obtain one of these machines that leaves your washing clean and fresh without the use of any detergents, you will be able to find such an appliance in South Arica. However, it does not come cheap. “It is a bit costly for residential use, but might be more accessible in the future,” states Dr Vermaas, who is of the opinion that it is a more sustainable option for commercial laundries.

Detergency properties and colourfastness 

Recently, more research has been conducted on this topic, but with a focus on the detergency properties of the catholyte to clean different textile fibres (natural and synthetic). Catholyte, she explains, is water produced at the negative electrode with a high pH, low oxidation-reduction potential, containing alkaline minerals. It also has surface active agents that increase the wetting properties, and it is an antioxidant. 

“A master’s student in the department, Ketshepileone Matlhoko, will be submitting her dissertation at the end of November on the possibility of using the catholyte as a scouring agent to clean raw wool,” says Dr Vermaas. 

The department is also conducting studies to investigate the influence of both catholyte and anolyte on colourfastness.

*Graphic: Production of electrolysed water (Nakae and Indaba, 2000). Diagram: Supplied



News Archive

Suspension of the South African Doping Control Laboratory (SADoCoL) by the World Anti-Doping Agency (WADA)
2016-05-04

The senior leadership of the UFS and the management of the South African Doping Control Laboratory (SADoCoL) take note of the decision by the World Anti-Doping Agency (WADA) to suspend the laboratory’s accreditation to perform doping control analysis on biological samples of athletes and sportsmen and -women until 30 September 2016. During this time of suspension, all sport-related samples will be sent for analysis to the WADA accredited laboratory in Qatar until the accreditation of SADoCoL is re-established. Analysis according to WADA accreditation will therefore not be interrupted during the period of the suspension of the accreditation of SADoCoL.

The announcement by WADA on 3 May 2016 follows a voluntary decision by SADoCoL in March 2016 to temporarily close the laboratory for some of its routine analytical duties for six months, as from 1 April 2016. The decision was taken in consultation with the senior leadership of the UFS and other role players, especially the Department of Sport and Recreation of South Africa (SRSA) and the South African Institute for Drug-Free Sport (SAIDS). SADoCoL is a specialised service laboratory of the University of the Free State (UFS) and has been in existence for more than thirty years.

Due to the ever-increasing demands on the number, variety and analytical sensitivity of compounds to be analysed according to the Prohibited List of WADA, technical and infrastructure adaptations need to be implemented in the laboratory continuously to keep up with the demands. Over the last year, SADoCoL has drastically increased its capacity in both personnel and infrastructure, to a point where these changes can be implemented for optimal performance of the laboratory.  This has to be done while normal routine analysis continues, and it became clear that at present, implementation cannot be successfully accomplished together with the workload from normal routine analyses.

The time of suspension will be utilised to implement and test these new systems in order to achieve the standard presently required by WADA, as well as to perform development and improvements.  This development will be performed in close collaboration with other role players in the anti-doping movement in South Africa, such as SAIDS and SRSA. Scientific development aid will also be acquired from other doping control laboratories worldwide in order to assure that the high analytical quality is maintained and expanded to meet the fast growing challenges in this field. The progress of the process will be closely monitored, and the upgraded methodologies will then, after rigorous testing, be implemented to ensure that the required analytical quality is maintained so as to obtain re-accreditation by WADA at the conclusion of the suspension period.

Issued by: Lacea Loader (Director: Communication and Brand Management)
Telephone: +27(0)51 401 2584 or +27 (0) 83 645 2454
E-mail: news@ufs.ac.za
Fax: +27 (0) 51 444 6393

We use cookies to make interactions with our websites and services easy and meaningful. To better understand how they are used, read more about the UFS cookie policy. By continuing to use this site you are giving us your consent to do this.

Accept