Latest News Archive

Please select Category, Year, and then Month to display items
Previous Archive
15 September 2022 | Story André Damons | Photo André Damons
Dr Osayande Evbuomwan, Prof Willy Vangu and Dr Gerrit Engelbrecht
Dr Osayande Evbuomwan, nuclear medicine specialist and Senior Lecturer, left, and Dr Gerrit Engelbrecht, Clinical Head of the Department of Nuclear Medicine at the UFS, right, with Prof Willy Vangu, Chief Specialist and Head of Nuclear Medicine at the University of the Witwatersrand, after his lecture.

There is no doubt that an institution like the University of the Free State (UFS), with its calibre and pedigree, needs a PET/CT machine (medical-imaging device that simultaneously and clearly reveals both anatomical details and metabolic processes within the body), particular in oncology, in improving the management of patients. 

This is according to Prof Willy Vangu, Chief Specialist and Head of Nuclear Medicine at the University of the Witwatersrand, who was a guest lecturer on 8 September 2022 at the Department of Nuclear Medicine at the UFS.

Positron emission tomography (PET) is a type of nuclear medicine imaging modality that measures the metabolic activity of the cells of body tissues. PET imaging is useful in the evaluation of patients with neurological, cardiac, infection, inflammation, and most importantly oncological conditions. Through its ability to detect metabolic changes very early, it can detect disease conditions that might not be easily detected on other forms of anatomical imaging.

Role of PET/CT in different clinical scenarios

In his lecture, Prof Vangu talked about the role of PET/CT in different clinical scenarios. By giving practical examples, he explained the role of PET/CT in different aspects of clinical medicine, including brain imaging for dementia, movement disorder and cerebrovascular reserve. 

“Looking at dementia, we will focus on one of diseases that is today becoming a major source of health concern, Alzheimer's disease. The latest Alzheimer's report that was published in 2018 stated that there are 50 million individuals currently suffering from Alzheimer's. They forecast that in 30 years we are going to have more than 150 million people suffering from this disease. PET/CT imaging can identify very early the typical patterns associated with all the different types of dementias, including Alzheimer's disease…”

For cardiac application, Prof Vangu said there are so many indications for PET/CT in cardiac imaging. One of the most important is the assessment of myocardial viability, in patients who have suffered from cardiomyopathy due to ischemic heart disease. PET/CT offers a noninvasive method of identifying viable myocardium that would benefit from revascularisation, with a very high diagnostic accuracy. 

Prof Vangu, who is also the head of nuclear medicine at the Charlotte Maxeke Johannesburg Academic and Chris Hani Baragwanath hospitals as well as head of the department for radiation sciences at the University of the Witwatersrand, said PET has been around for many years and is not something new. However, in clinical practice, PET imaging became significant with a breakthrough that occurred with the production of the glucose analogue tracer, 18F-fluorodeoxyglucose (FDG). This tracer in PET/CT imaging has revolutionised the management of cancer patients for the oncologist. It offers the ability of more accurate cancer staging, assessment of treatment response, assessment of disease recurrence and in some situations, surveillance. It has the ability to predict early which cancer patients will benefit from a particular drug, thereby giving the oncologist an idea on either to de-escalate treatment or change to a second line regimen very early on in the management. 

PET-CT scan imaging machine

An internet example of an image taken by a PET/CT machine. Photo for illustration: A PET/CT Imaging machine.


PET/CT came onto the market only in the year 2001, when it was launched for the first time by David Townsend (a physicist) and Ronald Nutt (electrical engineer). As at today, almost every institution in the country has at least one PET/CT machine.


“Looking at clinical applications, which is really the crux of the lecture today, there are so many clinical applications to talk about. You need a full week of a PET/CT symposium to go through all of them (and) maybe that might not even be enough. We can at least from this talk have an idea on how PET/CT can be applied in clinical medicine,” said Prof Vangu.

No other road for the university but to get a PET/CT machine

He also showed the impact and results that PET/CT imaging had in the management of infection and inflammation including TB. He said the role of PET/CT in TB is for monitoring of treatment, identification of extrapulmonary TB and prognosis. 

In concluding his lecture, he said there is no other road for the university but to get a PET/CT machine. “There is no argument about it. The institution needs it to improve the management of patients, especially the oncology and cardiology patients. Confidently making the decision on which patients to treat, how to treat them, identifying and evaluating their true response to therapy requires a PET/CT machine.

“I am happy to hear that the policy- and decisions-makers in the province and the university are looking forward to having a PET/CT machine,” he said later. 

Dr Osayande Evbuomwan, nuclear medicine specialist and Senior Lecturer, and Dr Gerrit Engelbrecht, Clinical Head of the Department of Nuclear Medicine at the UFS, are both looking forward of having a PET/CT in the department because in addition to its use in clinical setting, it has a huge role to play in research and training postgraduate students, as PET/CT imaging makes up a huge chunk of the postgraduate training curriculum

News Archive

Bloemfontein's quality of tap water compares very favourably with bottled water
2009-08-04

The quality of the drinking water of five suburbs in Bloemfontein is at least as good as or better than bottled water. This is the result of a standard and chemical bacterial analysis done by the University of the Free State’s (UFS) Centre for Environmental Management in collaboration with the Institute for Groundwater Studies (IGS).

Five samples were taken from tap water sources in the suburbs of Universitas, Brandwag, Bain’s Vlei, Langenhoven Park and Bayswater and 15 samples were taken of different brands of still and unflavoured bottled water. The samples were analysed at the laboratory of the IGS, while the interpretation of the analysis was done by the Centre for Environmental Management.

“We wanted to evaluate the difference in quality for human consumption between tap water and that of the different brands of bottled water,” said Prof. Maitland Seaman, Head of the Centre for Environmental Management.

“With the exception of two samples produced by multinational companies at their plants in South Africa, the different brands of bottled water used for the study were produced by South African companies, including a local small-scale Bloemfontein producer,” said Prof. Seaman.

According to the labels, the sources of the water vary from pure spring water, to partial reverse osmosis (as an aid to standardise salt, i.e. mineral, content), to only reverse osmosis (to remove salts). (Reverse osmosis is a process in which water is forced under pressure through a pipe with minute pores through which water passes but no – or very low concentrations of – salts pass.)

According to Prof. Seaman, the analysis revealed some interesting findings, such as:

• It is generally accepted that drinking water should have an acceptable level of salt content, as the body needs salts. Most mineral contents were relatively higher in the tap water samples than the bottled water samples and were very much within the acceptable range of drinkable water quality. One of the bottled samples, however, had a very low mineral content, as the water was produced by reverse osmosis, as stated on the bottle. While reverse osmosis is used by various producers, most producers use it as an aid, not as a single method to remove nearly all the salts. Drinking only such water over a prolonged period may probably have a negative effect on the human physiology.

• The pH values of the tap water samples (8,12–8,40) were found to be slightly higher (slightly alkaline), like in all south-eastern Free State rivers (from where the water is sourced) than the pH of most of the bottled water samples, most of which are sourced and/or treated in other areas. Two brands of bottled water were found to have relatively low pH levels (both 4,5, i.e. acidic) as indicated on their bottles and as confirmed by the IGS analysis. The health implication of this range of pH is not significant.

• The analysis showed differences in the mineral content given on the labels of most of the water bottles compared to that found by IGS analysis. The possibility of seasonal fluctuation in content, depending on various factors, is expected and most of the bottling companies also indicate this on their labels. What was a rather interesting finding was that two pairs of bottled water brands claimed exactly the same mineral content but appeared under different brand names and were also priced differently. In each case, one of the pair was a well-known house brand, and the other obviously the original producer. In one of these paired cases, the house brand stated that the water was spring water, while the other (identical) “original” brand stated that it was spring water treated by reverse osmosis and oxygen-enriched.

• Nitrate (NO3) levels were uniformly low except in one bottled sample, suggesting a low (non-threatening) level of organic pollution in the source water. Otherwise, none of the water showed any sign of pollution.

• The bacterial analysis confirmed the absence of any traces of coliforms or E.coli in any of the samples, as was also indicated by the bottling companies. This is very reassuring. What is not known is how all these waters were sterilised, which could be anything from irradiation to chlorine or ozone treatment.

• The price of the different brands of bottled water, each containing 500 ml of still water, ranged between R3,99 and R8,99, with R5,03 being the average price. A comparison between the least expensive and the most expensive bottles of water indicated no significant difference in quality. In fact, discrepancies were observed in the most expensive bottle in that the amount of Calcium (Ca) claimed to be present in it was found to be significantly different from what the analysis indicated (29,6 mg/l versus 0,92 mg/l). The alkalinity (CaCO3 mg/l) indicated on the bottle was also found to differ considerably (83 mg/l versus 9,4 mg/l). The concentration of Total Dissolved Salts (TDS) was not given on the product.

“The preference for bottled water as compared to Bloemfontein’s tap water from a qualitative perspective as well as the price discrepancy is unjustifiable. The environmental footprint of bottled water is also large. Sourcing, treating, bottling, packaging and transporting, to mention but a few of the steps involved in the processing of bottled water, entail a huge carbon footprint, as well as a large water footprint, because it also requires water for treating and rinsing to process bottled water,” said Prof. Seaman.

Media Release
Lacea Loader
Deputy Director: Media Liaison
Tel: 051 401 2584
Cell: 083 645 2454
E-mail: loaderl.stg@ufs.ac.za  
3 August 2009

 

We use cookies to make interactions with our websites and services easy and meaningful. To better understand how they are used, read more about the UFS cookie policy. By continuing to use this site you are giving us your consent to do this.

Accept